* Approximate values, not to scale. Refer to individual gauge full specifications prior to selection/purchase.

Active Gauges

Pirani High Performance
Atm. - 10-4 mbar

Ion
10-2- 10-10 mbar

Wide Range (Hot Cathode)
Atm. - 10-10 mbar

Handheld Pirani
1200 - 5x10-4 mbar

Linear Convection
1333 - 3x10-4 mbar

Strain Gauge
2000 - 1 mbar

Penning
10-2 - 10-9mbar

Penning (RS232/485)
10-2 - 10-9 mbar

Wide Range
10-3 - 10-9 mbar

Wide Range (RS232/485)
Atm. - 10-9 mbar

Thermocouple
65 - 1.3x10-3 mbar

Analogue Gauges

CG16K Dial
0-1040 mbar

CG16K Dial
0-125 mbar

CG16K Dial
0-50 mbar

CG16K Dial
0- 25 mbar

Barocel - Capacitance manometer gauges

Capacitance
0.2 -0.5 % accuracy

Capacitance
1 % accuracy

Capacitance
0.15 % accuracy

Capacitance
0.2 -0.4 % accuracy

Controllers

Active Digital Controller

Active Digital Controller

Instrument Controller

Passive Pirani/Penning Controller

Passive Pirani/Penning Controller

Passive Gauges

Pirani
1000 to 5x10-4 mbar

Penning
10-2 to 1x10-9 mbar

Ion
10-2 to 2x10-11mbar

Ion
10-4 to 2x10-12mbar

Pressure range

Gas independent

Bakeable

Phisical Principle

Flange

Temperature range Operating

Temperature range Storage

Variants

mbar

 

 

 

 

ºC

ºC

APG

Atm to 10⁻⁴

No

Yes*

Pirani

NW16/NW25/DN16CF/ Bare tube/ 1/8", 4/8VCR

5 to 60

-30 to 70

Electrical/digital/fieldbus

APGX-H

1333 to 3 x 10⁻⁴

No

Yes*

Pirani

NW16 / NW25 / 1/8NPT

5 to 60

-30 to 70

Electrical

P3

1200 to 5x10⁻⁴

No

No

Piezo - Pirani

NW16

5 to 50

20 to 60

Electrical / Digital

ASG2

2000 to 1

Yes

No**

Diaphragm

NW16 / 1/8 NPT

-40 to +80

-40 to +80

Electrical

ATC

65 to 1.3 x 10⁻³

Yes

No

Thermocouple

1/8" NPT

6 to 300

cool dry place

Electrical

AIM

10⁻² to 10⁻⁹

No

No

Inverted magnetron

NW25

5 to 60

0 to 70

Electrical/digital/fieldbus

WRG

Atm to 10⁻⁹

No

No

Inverted magnetron-pirani

NW25 / CF40

5 to 60

0 to 70

Electrical /Digital

WRH

1000 - 5x10⁻¹⁰

indirect gas dependent

 

Pirani - Bayard Alpert

NW25 / NW40 / DN40CF

5 to 60

40 to 65

Electrical

AIGX

6.6 x 10⁻² - 10⁻¹⁰

No

Yes***

Ion

NW25 / NW16 / CF40

0 to 40

-30 to 70

Electrical

* Bake-out with electronics removed     ** Do not exceed the storage temperture conditions     *** 200⁰C with electronics removed

Pressure range

Gas independent

Bakeable

Flange

Temperature range

Phisical Principle

mbar

ºC

CG16K

0-1040

Yes

No

NW16

10 to 50

CG16K

0-125

Yes

No

NW16

10 to 50

CG16K

0-50

Yes

No

NW16

10 to 50

CG16K

0-25

Yes

No

NW16

10 to 50

Barometrically Compensated Capsule Dial Gauge

Pressure range

Gas independent

Bakeable

Flange

Temperature range operating

Temperature range storage

Variants

Phisical Principle

mbar

ºC

ºC

Barocel7025

1000 / 100 / 10 / 1 / 0.1

Yes

Yes *

NW16 / 8VCR

10 to 40

-40 to 65

Digital (D-Sub 15 pin)

capacitance diaphragm gauge

Barocel7025M

1000 / 100 / 10

Yes

Yes *

NW16 / 8VCR

10 to 40

-40 to 65

Digital (D-Sub 15 pin)

capacitance diaphragm gauge

Barocel7045

1000 / 100 / 10 / 1 / 0.1

Yes

Yes *

NW16 / 8VCR

10 to 40

-40 to 65

Digital (D-Sub 15 pin)

heated capacitance diaphragm gauge (45⁰C)

Barocel7100

1000 / 100 / 10 / 1 / 0.1

Yes

Yes *

NW16 / 8VCR

10 to 40

-40 to 65

Digital (D-Sub 15 pin)

heated capacitance diaphragm gauge (45⁰C)

* < 110⁰C at the flange

Pressure range

Gas independent

Bakeable

Flange

Temperature range operating

Temperature range storage

Variants

Phisical Principle

mbar

ºC

ºC

PRG20K

1000 - 5x10⁻⁴

No

No

NW16 / CF16

0 to 40

-20 to 60

Electrical

thermal conductivity technology
according to Pirani

CPG35K

10⁻² to 10⁻⁹

No

Yes (CPG35KB only)

NW40 / CF40

0 to 80

-25 to 80

Electrical

cold cathode ionization technology according to Penning

IG40 BA

10⁻² to 10⁻¹¹

         

Yes *

CF40

20 to 80

-20 to 60

Electrical

Bayard Alpert

IG40 EX

10⁻⁴ to 10⁻¹²

       

Yes

CF40

20 to 80

-20 to 60

Electrical

Extractor

*Bakeable (up to 200 °C) gauge head cables to IG

Electrical Supply

Power consumption

Maximum operating altitude

Ambient operating temperature range

Channels

Interface

Gauge compatibility

Display

m

ºC

ADC Standard

100 to 240 V a.c. 47 to 63 Hz

15 W maximum

2000

0 to 40

1

Analog

APG100-XM, APG100-XLC, APG-L, APG-M, APG-MP, APGX-H, APGX-L, APGX-M, APGX-MP and WRG

High brightness green LED 7-segment display LED enunciators for units and display mode

ADC Enhanced

100 to 240 V a.c. 47 to 63 Hz

15 W maximum

2000

0 to 40

2

RS232

APG100-XM, APG100-XLC, APG-L, APG-M, APG-MP, APGX-H, APGX-L, APGX-M, APGX-MP , WRG, AIM-S, AIM-X and ASG

High brightness green LED 7-segment display LED enunciators for units and display mode

TIC

90 to 264 V a.c. 47 to 63 Hz

55 VA max

3000

0 to 40

3

RS232/485

APG100-XM, APG100-XLC, APG-L, APG-M, APG-MP, APGX-H, APGX-L, APGX-M, APGX-MP , WRG, AIM-S, AIM-X, ASG and AIGX**

High brightness green LED; option to 1, 3 or 6 channels simultaneously; assigns a four character alphanumeric name for each gauge; units in mbar, Torr, Pa or Volts

TIC

90 to 264 V a.c. 47 to 63 Hz

160 VA max

3000

0 to 40

6

RS232/485

APG100-XM, APG100-XLC, APG-L, APG-M, APG-MP, APGX-H, APGX-L, APGX-M, APGX-MP , WRG, AIM-S, AIM-X, ASG and AIGX**

High brightness green LED; option to 1, 3 or 6 channels simultaneously; assigns a four character alphanumeric name for each gauge; units in mbar, Torr, Pa or Volts

TIC (Capman)*

90 to 264 V a.c. 47 to 63 Hz

160 VA max

3000

0 to 40

6

RS232/485

Up to 6 active gauges including: APG, APGX, ATC, ASG, AIM, WRG, AIGX and Capacitance Manometers 7025, 7025M, 7045 and 7100

High brightness green LED; option to 1, 3 or 6 channels simultaneously; assigns a four character alphanumeric name for each gauge; units in mbar, Torr, Pa or Volts

* must include D40003050 adaptor for each Barocel       ** up to 3 but only 1 in degas

Electrical Supply

Power consumption

Maximum operating altitude

Ambient operating temperature range

Channels

Interface

Gauge compatibility

Display

W

m

ºC

PGC201

100 - 240 V a.c.

< 10

2000

5 to 50

3

RS232/485

1 or 2x PRG and just 1x CPG

digital, 7 segment LED, 4 digit mantissa and 2 digit exponent

PGC202

100 - 240 V a.c.

< 60

2000

5 to 50

3

RS232/485

1 or 2x PRG and just 1x IG